ekorRPS

Power Networks Protection

ekorRPS

Multifunctional protection unit, it acts as an independent protection, measurement and control unit or integrated in a protection and control system.

Technical Features:

  • Protection Functions:
    • Over current
      • Phase over current (3X50/51)
      • Earth faults (50Ns/51Ns)
      • Sensitive earth faults (50Ns/51Ns)
      • Directional phase over current (3X67)
      • Directional neutral over current (67N)
      • Directional isolated neutral over current (67NA)
      • Thermal image (49)
      • Current unbalance protection (46-46FA)
      • Cold Load Pickup
      • Voltage-restrained Time over current (51V)
      • Voltage regulation (50CSC)
      • Breaker failure (50BF)
    • Undercurrent (37)
    • Voltage:
      • Over voltage protection (59)
      • Under voltage protection (27)
      • Zero-sequence over voltage (59N)
      • Maximum and minimum frequency (81M/m)
      • Synchronism (25)
      • Voltage un balance (47)
    • Frequency
      • Maximum and minimum frequency (81M/m)
      • Frequency rate (81R)
    • Power (32)
      • Max/min active power
      • Max/min apparent power
      • Active/reactive power inversion
  • Logic functions and automation
    • Recloser (79)
    • Switch monitoring
    • Trip and closing circuit monitoring
    • Synchronism checking
    • Configurable inputs/outputs
    • Programable logics
    • Others
      • Protection status self-checking
      • Configuration of up to 6 setting tables
  • Metering
    • Phase, neutral and sensitive neutral current metering
    • Single and compound voltage metering
    • Active, reactive and apparent power metering
    • Active and reactive energy metering
    • Power factor metering
    • Maximum current indicator
    • Negative sequence metering (I2/I1) as a %
    • Total Harmonic Distortion (THD)
  • Data Acquisition
    • Event chronological logging
    • Fault chronological logging
    • Log of maximum and minimum meterings
    • Oscilloperturbograph
  • Communications:
    • IEC 60870-5-103
    • IEC 60870-5-101
    • ModBUS RTU
    • DNP3.0
    • PROCOME
    • HARRIS
    • Ports: RS485 and O.F.

 




Protection
MV client supply ekorRPG ekorRPT Protections for Switching Substations and Industrial Clients ekorRPS ekorRPGci Protection for rural Transformer Substations (CTR) ekorRPT-K Engine-generator set protection unit ekorUPG Substation Protection ekorRPS-TCP
Automation and Remote control
Remote control ekorUCT ekorCCP ekorRCI Automatic Transfers ekorSTP ekorCCP ekorRTK Fault Detection ekorDPF Voltage Presence Acoustic Alarm System ekorSAS Secondary Switching Points Secondary Switching Points
Control Area
Dispatching Centre
Software
ekorSOFT
Services
Protection, Control and Automation


asesoramiento
Do you need advice?

If you need help please fill in the following form.

Advice form
Grupo Ormazabal
© www.ormazabal.com